Description
Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab dokumentasi.
Spesification
H21-002 - HOBO Micro Station Data Logger
- Operating Range: -20° to 50°C (-4° to 122°F) with alkaline batteries, -40° to 70°C (-40° to 158°F) with lithium batteries
- Sensor Inputs: Up to four smart sensors (including multiple-parameter sensors)
- Communication: 3.5 mm serial port
- Dimensions: 8.9 cm H x 11.4 cm D x 5.4 cm W (3.5 x 4.5 x 2.125 inches)
- Weight: 0.36 kg (0.8 lb)
- Memory: 512K nonvolatile flash data storage
- Memory Modes: Stop when full, wrap around when full
- Operational Indicators: Seven lights provide logging and sensor network status
- Logging Interval: 1 second to 18 hours, user-specified interval
- Battery Life: 1 year typical use (up to 4 sensors with 1 minute or longer logging
interval) - Battery Type: Four standard AA alkaline batteries included (for operating conditions -20° to 50°C [-4° to 122°F]); optional AA lithium batteries available for operating conditions of -40° to 70°C (-40° to 158°F)
- Time Accuracy: 0 to 2 seconds for the first data point and ±5 seconds per week at
25°C (77°F) - Data Type: Supports measurement averaging based on availability of
supporting data from sensor - Logger Start Modes: Immediate, push-button, or delayed start options
- Data Communication: Current reading while logging, offload while logging, or offload
when stopped - Environmental Rating: Weatherproof, with GoreTM Vent for deployment in harsh weather conditions
- Mounting: Mount vertically on flat surface 18 cm (3.5 inches) or wider; optional mast mounting kit for use on 4.1 cm (1 5/8 inches) diameter masts
- Enclosure Access: Cover secured by four screws
- Sensor Network Cable Length: 100 m (328 ft) maximum
S-UCC-M001 - Electronic Switch Pulse Input Adapter - 1 meter
- Maximum Input Frequency: 120 Hz (120 pulses per second)
- Measurement Range: 0 – 65,533 pulses per logging interval
- Resolution: 1 pulse
- Lockout time: 45 µs ± 10%
- Recommended Input Type: Electronic solid state switch closure or CMOS-level digital output (example: FET, opto-FET or open collector)
- Preferred Switch State: Active low input Normally open
- Edge Detection: Falling edge, Schmitt Trigger buffer (logic levels: low ≤ 0.6 V, high ≥ 2.7 V)
- Minimum Pulse Width: 1 ms
- Input/Output Impedance: 100 KΩ
- Open Circuit Input Voltage: 3.3 V
- Maximum Input Voltage: 3.6 V
- User Connection: 24 AWG wires, 2 leads: white(+), black(-)
- Operating Temperature Range: -40° to 75°C (-40° to 167°F)
- Overall Cable Length: 1 m (3.3 ft.)
- Housing: Weatherproof PVC housing protects input adapter electronics
- Housing Dimensions: 14 x 0.95 cm (5.5 x 0.375 in.)
- Weight: 310 g (11 oz.)
- Bits per Sample 16
- Number of Data Channels: 1
- Measurement Averaging Option: No (reports the number of pulses over the logging interval)
T-MAG-SCT-050 - 0 - 50 AMP Split-core AC Current Transformer -0.75” Opening
- Measurement ranges: 0-50 Amps AC
- Accuracy: ±1% (from 10% to 130% of rated current)
- Voltage rating: 600VAC
- Phase angle:
- Output signal to FlexSmart TRMS Module: 0.333V at rated current
- Number of data channels: 1
- Quality construction:
- UL recognized
- 0.75” Opening
- Epoxy encapsulated housing
- Leads – 8-ft twisted pair, 22 AWGG
- Snap closing/opening
- Internal precision burden resistor
T-MAG-SCT-200 - 0 - 200 AMP Split-core AC Current Transformer - 1.25” Opening
- Measurement ranges: 0-200 Amps AC
- Accuracy: ±1% (from 10% to 130% of rated current)
- Voltage rating: 600VAC
- Phase angle:
- Output signal to FlexSmart TRMS Module: 0.333V at rated current
- Number of data channels: 1
- Quality construction:
- UL recognized
- 1.25” Opening
- Epoxy encapsulated housing
- Leads – 8-ft twisted pair, 22 AWGG
- Snap closing/opening
- Internal precision burden resistor
T-WNB-3D-240 - WattNode 208/240 VAC 3-phase Delta kWh Transducer
- Delta or Wye Configuration ranges: 208, 480 Volts AC
- 1 Phase 2 Wire 208V (No neutral)
- 1 Phase 2 Wire 240V (No neutral)
- 1 Phase 3 Wire 120V/240V
- 3 Phase 3 Wire 208V (No neutral)
- 3 Phase 4 Wire 120V/208V
- Rating: FCC Class A
- Operating: voltage range: ±20% of nominal
- Frequency: 60 Hz
- CT input: 0-0.5 VAC operating, 3 VAC maximum
- Accuracy: ±0.45% of reading + 0.05% FS through 25th harmonic (dependent on CT used and line variation accuracy could be 1.5% to 4% of reading)
- Enclosure: high impact, UL rated ABS plastic
- Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V
- Operating temp range: -30 to 60°C (-22 to 140°F)
- Operating humidity range: 0 to 90% RH, non-condensing
- Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.)
- Weight: 295 g (10.4 oz.)
- Number of data channels: 2