Description
DaqLink Temp / RH data logger adalah Data logger suhu kelembapan yang berdiri sendiri dengan antarmuka USB, menawarkan fungsionalitas yang kaya dalam ukuran yang kompak. Dengan sensor suhu dan kelembaban built-in ditambah empat input eksternal yang masing-masing mampu mengukur tegangan, arus, suhu, pulsa dan frekuensi, DaqLink Temp / RH menyediakan solusi pencatatan data yang efektif dan akurat. Untuk pemantauan indoor atau outdoor terus menerus, DaqLink adalah alat pilihan.
Feature
- Up to 6 measuring inputs with 16-bit resolution
- Real-time data streaming via USB to PC or cyclic storage to onboard memory
- Onsite data monitoring with two-row LCD
- Keypad with Run/Pause logging option
- Four level alarm configuration with email/SMS notification and onboard alarm buzzer
- Long-lasting rechargeable battery for standalone monitoring
- Supported by DataSuite software for data analysis and device setup
Spesification
INPUT TYPES |
|
4-20 mA
|
• Range: 4 to 20 mA • Resolution: 47.6 μA • Accuracy: ±0.5 % • Loop impedance: 21 Ω |
0 to 50 mV
|
• Range: 0 to 50 mV • Resolution: 37 μV • Accuracy: ±0.5 % • Input impedance: 25 MΩ • Max voltage: 3.2 V |
0 to 1 V
|
• Range: 0 to 1 V • Resolution: 200 μV • Accuracy: ±0.5 % • Input impedance: 25 MΩ • Max voltage: 3.2 V |
Temperature PT-100 (2-wires)
|
• Range: -200 to 400 ?C • Resolution: 0.1 ?C • Accuracy: -60 to 60 ?C: ±0.3 ?C 60 to 400 ?C: ±0.5 % |
Temperature Thermocouple J
|
• Range: -200 to 1,000 ?C • Resolution: 0.1 ?C • Accuracy: -60 to 60 ?C: ±0.5 ?C 60 to 1,000 ?C: ±0.5 % • Cold junction compensation error: ±0.3 ºC |
Temperature Thermocouple K
|
• Range: -200 to 1,000 ºC • Resolution: 0.1 ?C • Accuracy: -60 to 60 ?C: ±0.5 ?C 60 to 1,000 ?C: ±0.5 % • Cold junction compensation error: ±0.3 ?C |
Temperature Thermocouple T
|
• Range: -200 to 400 ?C • Resolution: 0.1 ?C • Accuracy: -60 to 60 ?C: ±0.5 ?C 60 to 400 ?C: ±0.5 % • Cold junction compensation error: ±0.3 ?C |
Frequency (input 4 only)
|
• Range: 20 Hz to 4 KHz • Input signal: 0 to 5 V • Input impedance: 470 Ω |
Pulse Counter (input 4 only)
|
• Range: 1 to 65,536 counts • Resolution: 1 count • Frequency range: 0 to 4,000 Hz • Input signal: 0 to 3.2 V • Input impedance: 470 Ω |
Contact |
• Range: Open/Closed |
Internal Temperature
|
• Range: -20 to 50 ?C • Accuracy: ±0.5 ?C • Resolution: 0.1 ?C |
Internal Humidity
|
• Range: 5 to 95 % RH • Accuracy: ±3 % at 10 to 90 % RH ±5 % at 5 to 10 % RH and 90 to 95 % RH • Resolution: 0.5 % RH |
OUTPUTS |
|
External Power Excitation (transducers usage) |
• 12 VDC @ 300 mA • Reset fuse overload protection |
Dry Contact Alarm Output
|
• Open collector • Close position resistance: 50 Ω • Max. Load: 50 mA, 3 V DC |
LOGGER SAMPLING FEATURES |
|
|
• Memory capacity: ~59,000 samples (depending on logger configuration) • Sampling rate: One every second to one every 18 hours • Channel separation: 80 dB |
HARDWARE SPECIFICATIONS |
|
Display |
• 2-row LCD • 16 character display |
Memory Modes
|
• Cyclic/Non-cyclic • Push to Run • Pause logging |
Power Supply
|
• Internal rechargeable 4.8 V, 800 mAh NiMH battery • External 12 V DC input @ 300 mA 3.6 VA • Battery Life: Up to 10 months, depending on logger configuration |
Operating Temperature Range
|
-20 to 50 ?C |
PC Communication
|
• USB 2.0 compliance • Mini USB type B cable |
Casing
|
• Plastic PC-ABS • Dimensions: 104 x 93 x 27 mm • Weight: 153 g • Supports table and wall mounting |
Man Machine Interface |
• Two-button keypad operation |
Standards Compliance |
• CE, FCC, IC Canada • Water and dust proof: IP54 |